Low Voltage Control: Dry contact RJ11 data cable wiring troubleshooting exclusive method for curtain motor

Dry Contact ControlDry contacts are used to transmit signals without transmitting power and are typically used to trigger other devices or to perform control operations. In our company, dry contact control also is used in our curtain motor and roller blind motor (tubular motor), you can check here.

It is one of the Low voltage control way, also is the wired control way. It requires a data cable to transmit the signal.

RJ11: 4 Pin. Registered jack (RJ) is a standardized telecommunication network interface.

So, what is Dry contact RJ11 data cable wiring troubleshooting exclusive method for curtain motor?

Find out the COM wire first, then short touch wire as follow:

  • ①. If the B and D are connected can turn on the tubular blind motor, then D is the COM wire.
Low Voltage Control: Dry contact RJ11, tubular motor dry contact

Steel wire: Please connect with conductive metal.

Dry contact test, Steel wire
Dry contact data cables wiring definition
  • ②. If the A and C are connected can turn on the tubular blind motor, then A is the COM wire.
Low Voltage Control: Dry contact RJ11, tubular motor dry contact

Steel wire: Please connect with conductive metal.

The COM wire can be identified by the above method, and the data cable end can be identified as good or not.

  • If the above control is worked by option ① , then the Connection Port please follow the following sequence to wiring
Low voltage, Dry contact data cables wiring definition
low voltage control: Dry contact data cables wiring definition
  • If the above control is worked by option② , then the Connection Port please follow the following sequence to wiring
low voltage control: connection port
low voltage control: Dry contact data cables wiring definition

All of the above are adjusted and the control data cable is re-inserted, then the control test is performed to see if it works well with the motor.

low voltage control: Dry contact data cables wiring definition, curtain motor and tubular motor

Curtain motor and Tubular motor dry contact control – data cables wiring definition.

Check details illustration:

Table of Contents

Related Wiki

Curtain motor data cable control RJ12

Tell us your needs & expectations